Victoreen 4000m+ Non-invasive X-ray Test Device/ Beam Analyzer

US $825.00

  • Tempe, Arizona, United States
  • Jan 29th
Zack's Ebay Store Key Features Measures kVp maximum, kVp average, kVp effective, dose and time in one exposure Compact, lightweight design Displays R or Gy External ion chambers for Mammo, CT, image intensifier and photo timing measurements Automatic exposure reset for hands off operation Rechargeable Ni-Cd batteries provide more than six hours of continuous service RS-232 computer interface Storage scope output for real-time waveform display Reversible display for fluoro measurements Product Description: Victoreen 4000M+ Non-Invasive X-Ray Test Device/ Beam Analyzer Condition: Used Technical Overview: Read the full Manual here.                       Product Specifications Kilovoltage Accuracy: 1 kV Mo/Mo (22 to 35 kVp Mammo generators w/30 µ Mo Range: W/Al Tubes: 27 to 155 kVp Mo/Mo Tubes: 21 to 50 kVp Time Description: Measured during entire exposure at 90% rise/fall of waveform Accuracy: Within 2% or 2 ms, whichever is greater Range: 1 ms to 10 seconds Exposure Description: Measure during entire exposure; kvp corrected Accuracy: ± 5% Range: 10 mR to 10 R Fluoroscopic Rate Description: Measured over one second intervals during fluoro exposure Accuracy: ± 5% Range: 0.5 to 200 R/min Detectors kV: CsI/photodiode pair measures x-ray transmission through differential attenuators Time: Computed from kV waveform stored in memory against quartz crystal time base Exposure: Parallel plate ionization chamber Volume: 36 cm3 Window: 38 mg/cm2, 18.9 cm2 polycarbonate Calibration: Reference to a NIST traceable voltage divider and a calibrated exposure monitor during irradiation Display 16 character dot-matrix LCD Controls Description: Model 4000+ has five rocker switches On/Off: Power switch Radio/Fluoro: Select radiographic or fluoro operation High/Low: Select for sensitivity Roll: Roll thru data Exposure/All: Select exposure only for external ion chamber Mo/Mo or W/Al: Select anode/filter of x-ray tube Connectors Power: 9 VDC, 500 mA Scope: BNC for oscilloscope connection RS-232: DB-9 connector configured as DCE. BNC and banana plug for external Ion chamber Power Requirements 9 VDC 500 mA external supply. Rechargeable internal Ni-Cd batteries supply more than six hours of continuous service with overnight charge Dimensions 8.5 (w) x 9 (d) x 3 in (h) (21.5 x 23 x 7.6 cm) Weight Approximately 3.5 lb (1.59 kg) HVL Set Aluminum filters: 2.3, 1.0, and 0.3 mm External Chamber Accessories Radiographic Ion Chamber, 30 cm3 (Victoreen Model 6000-528): energy response: within 7% from 30 to 150 kVp (15 to 65 keV); cable: 15 ft (4.5 m); chamber dimensions: 4 x 4 x 0.54 in thick (10.2 x 10.2 x 1.4 cm) Mammographic Ion Chamber, 3.3 cm3 (Victoreen Model 6000-529): energy response: within 5% from 0.2 to 5.0 mm Al HVL (16 to 90 kVp); cable: 15 ft (4.5 m); chamber dimensions: 4 cm ? x 1.5 cm thick. This chamber meets the needs of the MQSA for an external transparent chamber. Option: Probe Holder (Model 6000-529-95) for BRH2 test stand Image Intensifier Ion Chamber, 150 cm3 (Victoreen Model 6000- 530B): energy response: ± 10% from 1.8 to 10mm Al HVL; cable: 10 ft (3.0 m); chamber dimensions: 6.26 x 8 x 0.63 in (15.9 x 20.6 x 1.6 cm) Scatter Ion Chamber, 400 cm3 (Victoreen Model 6000-532B): energy response: ± 5% from 32 to 662 keV; cable 10 ft (3.0 m); chamber dimensions: 6.26 x 8 x 0.63 in (15.9 x 20.6 x 1.6 cm) CT Ion Chamber, 3.2 cm (Victoreen Models 6000-100 and 500-100): energy response: ± 5% from 1 to 10 mm Al HVL; cable: 3 ft (0.9 m); sensitive length: 4 in (10.0 cm); chamber inside ?: 0.25 in (6.4 mm) CT High Sensitivity Ion Chamber, 10 cm3, for multislice CT (Victoreen Models 6000-200 and 500-200): energy response: ± 5% from 1 to 10 mm Al HVL; cable: 3 ft (0.9 m); sensitive length: 4 in (10.0 cm); chamber inside ?: 0.45 in (11.44 mm) Model Name Power Adapter 4000M+ X-Ray Test Device with AC adaptor (specify from the following) USA/Japan: 110 VAC 9 VDC 500 mA (14-301) Europe: 230 VAC 9 VDC 500 mA (14-339) UK: 230 VAC 9 VDC 500 mA (14-415) Australia: 230 VAC 9 VDC 500 mA (14-415) and adapter (14-416) Related Products 4000EXL Toolkit for Excel RS232 Cable 190004 07-434 Ultra-High purity HVL Attenuators   Carrying Case 4000-69 Shipping Information: We offer NEXT-DAY shipping (after receipt of payment) for all items in stock. Orders paid after 1pm MST will be processed the next business day. The shipping cost shown with this listing is an estimation that we strive to follow. If you would like a personalized shipping quote please message us. We sell some items that must be shipped freight, please contact us for more information on setting up freight shipment. Payment Information: We accept PayPal, Visa, MasterCard, American Express, and Discover. We can also accept wire transfer. For international transactions OR questions about any payment method, please contact us. Arizona buyers without a reseller's certificate will be charged 8.3% sales tax. Warranty and Returns: This item is sold with a 30 day DOA warranty, unless otherwise expressly stated in the listing. We are happy to issue a refund once we have received the returned item; for our complete return policy, click here. For some items we offer additional warranty protection for a negotiated fee; if you would like more information on this, please contact us. For more information on our warranty policies, click here. Note: To provide you with competitive pricing, we do not offer technical support. If an item does not work , click here to learn about how to return an item. Note: All units are sold as photographed and do not include any additional accessories such as power cables, remote controls, or software installed, unless otherwise specifically addressed in the listing details.   © 2014
Condition Used :
An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections.
Seller Notes Unit does NOT include power cable.

Directions

Similar products from Radiation Dose Meters & Detectors

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies