Vet Infusion Pump Veterinary Automatic Infusion Audible And Visible Alarm

US $439.00

  • BEIJING, China
  • Jan 30th
xsellx - qsellx US $329.00 US $629.00 US $629.00 US $629.00 US $329.00 US $629.00 US $429.00 US $1729.00 US $720.00 US $529.00 US $529.00 US $718.00 US $420.00 US $529.00 US $720.00 US $720.00 US $699.00 US $599.00 US $720.00 US $699.00 US $860.00 US $799.00 US $118.00 US $999.00 XSELLX Gallery  Vet Veterinary Automatic Infusion Pump  Model: IP-50V   Description: Features:          1. Audible and visual alarm for occlusion, empty, low battery, end of infusion, door open, wrong setting etc, which gain patents 2. HD LCD Display, high capacity words, friendly user interface, dynamically display working status 3. Compatible with any brand of infusion sets after correct calibration 4. Preset Solution Volume to greatly reduce the workload of nurses 5. Work mode: ml/h and drop/min can switch freely   6. Three levels of occlusion: high, middle and low 7. Purge function  8. KVO: KVO (keep-vein-open) automatically opens as infusion is completed. 9. Power Source: AC100-240V, 50/60Hz; Internal Battery 10.Automatically record the settings of last infusion can be available per customers' request 11. language: English, Poland, Latvian, Russian etc Specification:  1. Infusion Rate 0.1ml/h---1200ml/h (1ml/h step ,input 016 when set the rate from 800 to 1200ml/h) 2. Rate Accuracy within±5% (after correct calibration) 3. Purge Rate 100ml/h---1200ml/h(can be calibrated) 4. Volume Limit 0ml---9999ml   Total Infusion Volume  0---9999.9 ml 5. Alarm Pressure High:800mmHg±200mmHg(106.7kPa±26.7kPa)                              Medium:500mmHg±100mmHg(66.7kPa±13.3kPa)                              Low:300mmHg±100mmHg(40.7kPa±13.3kPa) 6. Alarms             end of injection, occlusion, door open, bubbles in the tube, wrong setting,                             low battery, AC power pulled out etc 7. Power source 100V---240V  50/60Hz  8. Internal rechargeable Li battery volume>=1,600mAh       4 hours internal battery backup   9. Bubble Detector ultrasonic wave detector, detection sensitivity >=25?L 10. KVO Speed 1ml/h---5ml/h (1ml/h step) 11. Power Consumption 15VA 12. Operation Environment Temperature  +5----+40 degree                                             Relative Humidity  20----90%                                               Storage Temperature  -30-----+55 degree                                             Humidity  

Directions

Similar products from Feeding & Infusion Pumps

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies