Positive Inversion Counter Meter + 400p/r Encoder + Meter Counting Wheel Set

US $117.99

  • SHENZHEN, China
  • Jan 29th
Product Description: Addition and subtraction Positive inversion counter meter + encoder + meter counting wheel set 500K frequency response CHINA MADE Technical characteristics KS800 type cable displacement display instrument is it includes position, control, display module, the biggest feature is its super counting frequency, can reach 500K. Can be widely used in industrial control field. The 96 X 48 x 115mm standard chassis, six 0.56 inch digital tube display. Input A and input B constitute a dual input, can identify the phase for the pulse encoder signal 90 degrees. Enter the single way switch signal (pulse) for counting (Dan Xiang) or speed. An external reset terminal, can be controlled by an external switch. The two control value, two relay outputs, which can be used to control or alarm. 4 kinds of optional relay output. Can be set to automatically reset time delay, automatic reset function. Peak display function. Can count / speed, is set by the internal parameters. Parameter setting password protection function. Current counting, set the value of power down without losing. Can be set to determine the input pulse rate, and display the value of the proportional relationship between the. The external sensor: Angle, line grating displacement sensor, sensor to provide 5V (100mA), 12V (100mA) power supply. Other voltage can be customized. The proximity switch or Holzer switch, can count on the pulse, only connected to the A terminal. Counting rate: single frequency, dual frequency, four octave optional (ratio value is 1 to four octave). Interpolation functions: can set 1 interpolation points, so as to realize the linear interpolation function. With 4~20mA current output function (optional). A 485 communication function. The communication baud rate of 9600bps, 0.5 seconds sends a display value (optional). Technical parameters Power supply voltage: AC220V 50Hz Input impedance: 5K Pulse frequency: ≤ 500K Magnification range: 0.000~999.999 Display range: -199999~199999 Pulse level: low level: -50V~0.5V high level: 3.5~50V Contact capacity: AC220V1A DC24V1A Installation: snap in Hole size: 92 x 43 5mm Environment temperature: -10 °C ~50 °C Explanation of parameters Pn000: the location of the decimal point (the display value in decimal digits). The default value is 2. Pn001: the counting rate. Is to determine the input and display the value of the proportional relationship between the. Range: 0.000~999.999. The default is 1. Count / speed mode role. Pn002: upper limit value. Is the count limit relay. The default is 1000 Pn003: lower limit value. Is the count limit relay. The default is -1000 Pn004: counting direction. The default value is 0, said the count forward. If the display value direction and the opposite situation, through adjusting the parameters to achieve consistency. Pn005: initial value. The display automatically save the previous power value. After the boot, the display value = initial value + count. The default value is 0. Pn006: parameter password protection. Non zero, parameters are password protected, you must enter the correct password to enter the parameters page, parameter modification. The default value is 0. Pn007: relay output mode, the default value is 1. Pn008: automatic reset time. When the parameter is not 0, when the display value ≥ Pn002 (upper limit), delay the setting time, the display value is automatically reset. The default value is 0, close the function. Set the minimum unit of time: 0.1S. Pn009: differential value of 0. The default is 0 Pn010: differential base. Formula: *Pn009/Pn010 = display value of measured value; the default is 0 Pn011:4mA output the corresponding numerical. The default is 0 Pn012:20mA output the corresponding numerical. The default is 10000 Pn013:4mA current offset adjustment (0~1000), the default value of 58 Pn014:20mA current adjustment coefficient: 800~1200. The default value of 1000. Pn015:0: counting mode; 1~20: speed mode, at the same time, this value determines the size of the filter frequency, numerical value is greater, the measured data is stable, but the update is slow, users can set up according to need. The default is 0 Pn016: input signal selection. 0: the input A, B two-phase orthogonal coding signal, which can be connected with the encoder or grating ruler. 1: only pulse on the A terminal on the count / speed. One way is to count the time (increased). To change this setting is required after re power to act. The default is 0 Pn019: restore factory settings. Enter the value 123, the instrument to restore factory settings. Note: 1 speed mode, the default display value refers to the second pulse number input, can be obtained by setting the appropriate value of the display unit count rate. Terminal description: O11: a normally closed contact of the relay 1. O12: intermediate relay 1. O13: relay 1 normally open contact. O21: a normally closed contact of the relay 2. O22: intermediate relay 2. O23: relay 2 normally open contact. B/-: for a 485 communication function of B line, negative electrode for 4~20mA current output. A/+: for a 485 communication function of A line, positive electrode for 4~20mA current output. A: orthogonal input signal A phase or single-phase counting pulse input terminal. B: orthogonal input signal B terminal. Z: the external reset signal terminal, active low. +5V:5V power supply terminal. GND: instrument public ground terminal. +12V:12V power supply terminal. 220VAC: instrument power supply, AC 220V ± 10% Operating instructions 1 in no password protection Press the function key (MO) for more than 2 seconds, enter parameter setting state, screen display the first parameter to Pn000, if the parameter to set back, can press the function key (MO), the parameters are incremented, circular display, parameter Pn0XX until you want to modify; When the screen can show the parameters of the Pn0XX, press the OK button (En) parameters Pn0XX into the set state, the screen will display the original setting value, and the last is flashing status; To modify the value, to determine the current revision is flashing, if not, can also press the function key (MO) from right to left order cycle change the flashing position, through ↑↓ keys to change the numerical value from 0 to 9 cycles; After setting parameter, press the OK button (En) out of the Pn0XX parameter setting, back to 1) state. On screen display Pn0XX, press the reset button (RST) can jump out the set state, to a working state. 2 in the password protection Press the function key, the screen display PASS, enter the password input state. And then press the OK button (En), the lowest flicker, referring to the operation, enter the correct password, press the OK button (En) to confirm, program into the parameter set state. If the password is wrong or press the reset button, the program to return to work. Peak function In the working status, press the down arrow keys, MAX indicator light, display value always display count peak. Press again the down arrow keys, MAX indicator lights, exit the peak state. Please do contact us before open case or leave negative feedback if any problems or questions. NOTED: Open source products, no information provided, no technical support offered. Shipping Policy The default shipping is by China Post air mail/Hongkong air mail. Item will be shipped within 2-3 working days after full payment is received. The delivery to most of the countries will take 3-6 weeks, if there's no problem when pass through the customs.  It will take about 50 days or more to some places like South America,India,Mexico and Africa.  We only ship to the approved address given in PayPal payment. Please make sure payment address in PayPal is correct.  Any non-received items caused by invalid address registered on PayPal are not in our full refund or replacement policy.  The extra fee occured when the product pass through the customs should be paid by buyer Payment & Return Policy We accept Paypal as the payment method.  If you can't receive the product within 2 month (60 days), please contact with us,we promise to payback 100% of your money. We ensure our products work normally before post.If the products is broken before arrival to you,all you should do is taking a photo to show us our broken product.We promise to payback 100% of your money. If you don't satisfy with our product,please help to post our product back to us.You should pay the post back postage.After we receive our product,we promise to payback 100% of your money. inkfrog terapeak i000000

Directions

Similar products from Other Electronic Monitoring Devices & Assemblies

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies