Ohd 3000 Ce Fittester

US $470

  • Saint John, Indiana, United States
  • Mar 2nd
The FitTester 300 CE Introduction The FitTester 3000 CE measures face-to-facepiece fit of a respirator.  With a perfect respirator and fit, all inhaled air is forced through the filter system, thereby providing maximum respiratory protection for the individual.  If the face-to-facepiece seal leaks, unfiltered air bypasses the filter system and enters the individual’s lungs during inhalation, thus reducing respiratory protection. By design, a respirator should prevent contaminated air from entering the lungs of the individual wearing it.  If the respirator is in good working order, the only way contaminated air can enter the individual’s lungs is through a leak in the face-to-facepiece seal.  The FitTester 3000 CE measures face-to-facepiece seal leakage and then calculates the fit factor (FF) of the respirator being tested. The FitTester 3000 CE uses the patented Controlled Negative Pressure (CNP) technology.  An adapter configured with a squeeze-bulb-actuated valve replaces the filter cartridge and inhalation valve on the respirator.  The Individual under test dons the respirator, takes a breath, hold the breath, squeezes the bulb to close the adapter valve, and begins the test.  It functions by creating and maintaining a negative pressure in the respirator mask.  This process may last up to 8 seconds.  Once the adapter valve is closed by squeezing and holding the attached bulb, sealing the respirator mask, the start key is pressed, allowing the FitTester 3000 CE to remove air from the respirator mask until the challenge pressure is reached.  At this point, it there isn’t a leak, the FitTester 3000 CE doesn’t remove any more air from the respirator.  If there is a leak, air enters the respirator mask, and the pressure rises.  Etc. This unit has been used very lightly.  The certification expired on 10/24/2013 and will need to be recertified through OHD.  All past paper work will be provided for ease of attaining recert. Also included with purchase will be three(3) ISI fit test masks with adapters. 1-small, 1-medium, 1-large.
This item is used but in perfect working order. Minor scuffs from use.
Brand OHD
Type Fit Testing equipment
Model 3000 CE
Country/Region of Manufacture United States

Directions

Similar products from Other Fire & Rescue Tools

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies