New Tes-92 Emf Tester Electrosmog Meter Radiation Detector

US $140.00

  • Guangzhou, China
  • Jan 29th
 New TES-92 EMF Tester ElectroSmog Meter Radiation Detector 50 MHz to 3.5 GHz frequency range. For isotropic measurements of electromagnetic fields. Non-directional (isotropic ) measurement with three-channel measurement probe. High dynamic range due to three-channel digital results processing. Configurable alarm threshold and memory function. Easy to use High frequency (RF) electromagnetic wave field strength measurement. Mobil phone base station antenna radiation power density measurement. Wireless communication applications (CW , TDMA , GSM , DECT). Wireless LAN (Wi-Fi) detection, installation. Spy camera, wireless bug finder. Cellular/Cordless phone radiation safety level. Microwave oven leakage detection. Personal living environment EMF safety. RF power measurement for transmitters. ELECTRICAL SPECIFICATIONS Sensor type Electric field (E) Frequency range 50MHz to 3.5 GHz Directional characteristic Isotropic, 3-dimensional Measurement range (CW signal>50MHz) 38mV/m to 11V/m Absolute error(@1V/m and 50MHz) ± 1.0dB Frequency response (taking into account typ. CAL factor) ± 1.0dB (50MHz to 1.9 GHz) , ±2.4dB(1.9GHz to 35GHz) Isotropy deviation Type. ±1.0dB f>50 MHz Overload limit 4.2W/m2 (40 V/m) Temperature response(0 to 50 ) ± 1.5dB Note Unless otherwise stated, all specifications hold under the following assumptions: Sinusoidal signals; device in far-field of a source; probe head pointing toward source; ambient temperature +23 ±3 ;relative air humidity 25% to 75%. GENERAL SPECIFICATIONS Measurement method Digital , triaxial measurement Directional characteristic Isotropic, triaxial Measurement range selection One continuous range Display resolution 0.1mV/m, 0.1 ?A/m, 0.1 ?W/m?, 0.001 ?W/cm? Setting time Typically 1s ( 0 to 90% of meas. value) Display refresh rate Typically 400mS Display type LCD 4 digit Audible alarm Buzzer Measurement units mV/m , V/m , ?A/m , mA/m , ?W/m? , mW/m? , ?W/cm? Measurement display value Instantaneous measured value, maximum value or average value since power-on. Measurement average time (in per-set steps) 4s to 15 minutes Measurement alarm function Adjustable threshold with ON/OFF Measurement calibration factor CAL Adjustable Manual data memory and read storage 99 sets ( only recall by meter ) Battery 9V Battery life >15 hours Accessory  carrying case & manual

Directions

Similar products from Radiation Dose Meters & Detectors

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies