Mint Nrg Symphonie Data Logger Anemometer Wind Speed Energy Measurements Kit

US $199.99

  • Salt Lake City, Utah, United States
  • Mar 3rd
  Up for sale is a MINT NRG Symphonie Data Logger Anemometer Wind Speed Energy Measurements Kit. Comes with the NRG Data Logger, #40C Anemometer, and a Temperature SCM Card. This was used maybe once and is in Mint Condition.  Fully Functional. If you have any questions please feel free to contact me. Thanks for looking!! SYMPHONIE Symphonie NRG Logger with MMC and accessories Welcome to Symphonie, the industry's first Internet-enabled wind resource assessment data logger! The Symphonie NRG Logger is a flexible, twelve-channel wind energy data acquisition system that provides time-stamped data from up to 6 frequency output sensors and up to 6 analog sensors. Three anemometer and two wind direction channels are built in and up to seven "plug and play" Signal Conditioning Modules (SCM), purchased separately, may be installed into each Symphonie Logger to add additional sensors. Data is averaged every ten minutes, time stamped and stored on widely available 16MB MMC cards. MMC Cards (one MMC Card included) are capable of storing over one year of data. A real-time display and keypad are built into the logger to facilitate site visits. Symphonie is rugged and can be installed at environmentally harsh sites with confidence. Symphonie directly interfaces with your choice of communication iPacks to transfer data to your local Internet Service Provider (ISP). With an added communication iPack (AMPS Analog, GSM, Dial-up), it is not necessary to make a site visit to change the MMC Card. The data will automatically be transferred to an ISP and an email will arrive at your desk. All iPacks (Battery PV, Dial-up, AMPS, GSM) are designed to be "plug and play" with minimal hardware configuration necessary. Due to additional power requirements, choosing a BP-20 or RH SCM for a barometric pressure sensor or relative humidity sensor requires an iPack to provide the necessary 12V source. For more detail log on to http://www.nrgsystems.com Wind Monitor System Tubular wind mast Small wind generator NRG Systems   - NRG Symphonie Logger   - NRG Wind Explorer   - NRG #40 Anemometer   - NRG #200P Wind     Direction Vane   - NRG #Relative Humidity     Sensor   - NRG #110S Temperature     Sensor with Radiation     Shield   - NRG #BP20 Barometric     Pressure Sensor Portable Anemometers Loggers & Sensors Description Instrument type 12 channel internet-enabled micropower wind energy data logger Applications wind resource assessmentturbine power performance verification Sensor compatibility - counter channels NRG #40 Maximum anemometerrain gaugeopto anemometer (contact NRG for more information)reed switch anemometer (contact NRG for more information) Sensor compatibility - analog channels NRG 200P direction vaneNRG 110S temperatureLi-Cor 200SA pyranometerNRG BP-20 absolute pressure (requires optional iPack power) RH-5 relative humidity (requires optional iPack power) Data Collection Counter channels Channels 1 - 6 are always counter inputs:channels 1 - 3 dedicated for NRG #40 Maximum anemometer or compatiblechannels 4 - 6 use counter Signal Conditioning Modules (SCMs) to configure the channel for a particular sensor Analog channels Channels 7 - 12 are always analog inputs:channels 7 and 8 dedicated for NRG 200P (potentiometer) direction vanechannels 9 - 12 use analog Signal Conditioning Modules (SCMs) to configure each channel for a particular sensor Sampling interval 2 seconds Averaging interval 10 minute fixed Real time clock internal battery-backed with leap year correction, Y2K to 2099 Storage medium 16 MB MultiMedia Card (MMC), non-volatile FLASH Maximum data storage 664 days Parameters recorded for each channel each data interval is time-stampedaverage standard deviationminmax File format Windows compatible(1) 14 KB binary file per dayheader includes site, serial number and sensor information Software Symphonie Data Retriever for Windows (included)scales raw datacreates measurement database for each sitecreates basic reportsmaintains site and sensor informationconfigures iPacks Reader Windows compatible MMC reader (Item 3158) accesses MMC data as disk files Data delivery MMC cardsinternet email via GSM, AMPS or dial-up with optional iPack Resolution Analog measurement resolution 0.1% of full scale (1024 counts) Counter average stored resolution 0.1% of the value stored Analog average stored resolution 0.1% of the value stored Min / Max stored resolution 0.3% of the value stored Standard deviation stored resolution 4% of the value stored Configuration User interface Liquid Crystal Display (LCD) 4 x 20 characters16 key pad (6 navigation keys plus numeric/phone pad) with audible feedback Configurable parameters clock time zone site number display scaling (defaults are provided for each channel based on channel type) iPack options iPack configured via serial port connection to your PCSerial connection direct to iPack or through logger's iPack access portSymphonie Data Retriever for Windows integrates iPack settings Connections Sensor wiring sensors connect to field wiring panelfield wiring panel plugs into loggerground stud to connect to earth groundmale DB25 interfaces to one optional iPack communications moduleiPack access port facilitates field programming and accepts headset for voice calls3 SCM slots for counter SCMs 4 SCM slots for analog SCMs Power requirements Batteries (2) 1.5 Volt D-Cell Batteries (included)nominal voltage: 1.5 Voltsminimum voltage: 0.9 Voltsbattery life approximately one year, depending on configuration External power input provided by any iPack External solar input provided by any iPack Other optional iPacks provide 12V power required by some sensors. PV/Battery only iPack (Item 3166) provides power to sensors and logger for stand alone configurations. Installation Mounting Mounts with 4 bolts (included) to keyed slots inside of metal shelter boxshelter box attaches to tower with hose clamps Tools required screwdriver for sensor terminals, included5/16 inch nut driver3/8 inch nut driver Environmental Operating temperature range -40 °C to 65 °C (-40 °F to 149 °F) Note: display readable -30 °C to 55 °C (-22 °F to 130 °F) Operating humidity range 0 to 100% RH non-condensing Lifespan 10 years + Physical Weight 1.3 kg (2.6 pounds), including batteries Dimensions (Including Field Wiring Panel) 22.2 cm height, 18.8 cm width, 7.7 cm depth (8.7 x 7.4 x 3.0 in.) Materials Faceplate Injection molded black ABS Buttons white elastomer dome keypad Wiring panel fiberglass-epoxy terminal board, sealed gold plated pins, zinc plated screws and terminals Enclosure Weatherproof polycarbonate, meets the following specifications:NEMA type 4, 4X and 13 IEC: IP65
MINT CONDITION. Works Great! Comes with Temperature SCM Card and #40C NRG Anemometer.
Brand NRG
Model Data Logger

Directions

Similar products from Data Loggers and Data Acquisition Cards

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies