Impact Uni-vent 750 Portable Ventilator

US $140

  • Hurst, Texas, United States
  • Mar 7th
The Impact 750 Uni-Vent Portable Ventilator is powerful, dependable and used by healthcare professionals all over the world. This unit has powerful operating modes, full range control settings, comprehensive alarm systems, and AWR (Air Worthiness Release) is standard for both fixed and rotary wing aircraft.   Listing as used but everything included still in new packaging   Operating Modes: CONTROL- with/without PEEP, with/without SIGH; ASSIST CONTROL - with/without PEEP, with/without SIGH; SIMV - with/without PEEP, SIGH; CMV - for APNEA backup of ASSIST CONTROL and SIMV Flow Rate: Adjustable, 0 to approximately 100 LPM @ 50 psi Tidal Volume Range: 0 to 3000 ml Ventilation Rate: Adjustable, 1 to 150 breaths per minute, in 1 BPM increments (+/- 1 digit on the display panel) Inspiration Time: Adjustable, 0.1 to 3.0 seconds, in 0.1 second increments (+/- 1 digit on the display panel) Low Pressure Alarm: Adjustable, OFF to 50 cmH2O, in 1 cmH2O increments (+/- 1 digit on the display panel) High Pressure Alarm: Adjustable, 15 to 100 cmH2O, in 1 cmH2O increments (+/- 1 digit on the display panel) Peak Inspiratory Pressure Relief: Adjustable, 15 to 100 cmH2O, in 1 cmH2O increments (+/- 1 digit on the display panel) ASSIST/SIMV SENSITIVITY: Adjustable, -2.0 to -8.0 cmH2O, in -2 cmH2O increments AUTOmatic PEEP: Monitor range 1 to 20 cmH2O, in 1 cmH2O increments (+/- 1 digit on the display panel) MANUAL PEEP: Program range 1 to 20 cmH2O, in 1 cmH2O increments (+/- 1 digit on the display panel) SIGH: Occurs once every 100-ventilations or 7-minutes, whichever occurs first. SIGH = 150% of inspiration time (truncated to a combined maximum of 3-seconds) ALPHA/NUMERIC Displays: Rate, inspiration time, low pressure alarm, high pressure alarm, PEEP AUTOmatic, PEEP manual, peak airway pressure, mean airway pressure, Paw Digital Bar Graph: Display range -10 to 100 cmH2O, mixed resolutions Apha/Numeric Alarm Displays: Inverse I:E, memory check, transducer calibration, transducer calibration abort, FAL Manual Trigger: Operator controlled manual override of current operating mode EMI/RFI: Certified and includes aeromedical Temperature (operation/storage) & Humidity: Meets/exceeds MIL-STD-810E Operating Voltages Ventilator: Input: 11-30 volts, AC (50-400 Hz), Input: 11-30 volts, DC (positive or negative ground) Multivoltage AC Power Supply: Input: 115/230 VAC, 50-400 Hz, Output: Nominal 16 VDC, 1.5A (negative ground) Powered by eBay Turbo Lister The free listing tool. List your items fast and easy and manage your active items.
Condition:
Used: An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections. ...
Brand Impact
Model Uni-vent 750

Directions

Similar products from Nebulizers & Ventilators

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies