Gigatronics Fluke 6082a Synthesized Rf Signal Generator 100khz-2112mhz

US $1,800.00

  • Columbus, Ohio, United States
  • Jan 29th
Gigatronics 6082A Synthesized RF Signal Generator 100KHz-2112MHz Powers up, fan works, all buttons seem to work, display is clear. left lower cabinet damage, missing foot and left rear handle. Very heavy unit. Will ship in padded crate via Fedex Ground or Freight. This item is for US purchase only and cannot be exported. Please contact me with your offer. HIGH PERFORMANCE COMES STANDARD The 6080A and 6082A give you exceptional spectral purity. Phase noise at 1 GHz is-131 dBc/Hz at 20 kHz offset. Non-harmonic spuriousper-formance is -100 dBc at 1 GHz. And residual FM isa low 1.5 Hz, which is ideal for both high performance receiver test and LO substitution. The output level of19 dBm (+20 dBm with overranging) gives you all the power you need for receiver  overload tests, LO substitution,and for driving high level mixers At -140 dBm (-147 dBmwith underranging), the6080A and 6082A are ideal for receiver sensitivity or noise figure measurements.And low RF IMD makes both instruments ideal for receiver selectivity or SSB two-tone testing. Sweep Time: 30 ms +(0 ms or 10 ms to 10 s) per amplitude increment in 1, 2, 5 sequence. Total sweep time is time per amplitude increment x number of amplitude increments over sweep width. Sweep Modes: Auto, single, manual. X-axis Output: 0 to +10 V ±10%, 4096 max steps. Z-axis Output: TTL level, high during sweep retrace. REMOTE PROGRAMMING Interface: IEEE-488. Control Language: IEEE-488.2. Special emulation modes allow compatibility with Giga-tronics 6060 Series, Fluke 6060/6070 Series, or Hewlett-Packard 8642A/B. Select Code Range: 00-30. Interface Functions: SHI,AHI,T5,TE0, L3, LE0, SRI, RLI, PP0, DCI, DTI, C0, E2. Functions Controlled: All functions except internal/external reference and power switch. GENERAL Temperature Range: Operating: 0 to 50° C; Non-Operating: -40 to + 75° C. Operating Humidity: 0-95%, 0-30°C; 0-75%, 30-40° C; 0-45%, 40-50° C. RF Leakage: Complies with MIL-Std-461B method CEO3 and REO2; VDE 0871B; CISPR 22; FCC Part 15, class B. Also <0.5 µV into a two-turn loop 2.5 cm in diameter, at 2.5 cm from any surface, terminated in 50 ? load, at RF carrier frequency. Internal Diagnostics: The instrument monitors internal operations and alerts the user of most malfunctions which then can be traced to faulty modules and repaired. Calibration Interval: 2 years. Store/Recall memory: 50 non-volatile registers for storing, recalling and sequencing through complete front panel setup states. Secure Mode: Provides protection against unauthorized access to user-defined instrument state, instrument state registers and user compensation data. Includes optional display blanking and complete memory purging. Rear Panel Input/Output: Reference input and output BNC’s; 7-pin auxiliary connector for sweep x-axis drive and z-blank/penlift signal, and memory sequencing; IEEE-488 standard interface. Specify option 830 for rear panel RF output, AM input, FM and phase modulation input, pulse modulation input and modulation oscillator output. Power: 100, 120, 220, 240 V ±10%; 48-63 Hz; 200 VA. Weight: 6080A: 27 kg (60 lbs) net; 39 kg (85 lbs) shipping. 6082A: Add 11 kg (5 lbs). Dimensions: 133 mm H x 430 mm W x 597 mm D (5.25 in x 17 in x 23.5 in). ORDERING INFORMATION 6080A (.01 – 1056 MHz); 6082A (0.1 – 2112 MHz) Options: 130 High Stability Reference 132 Medium Stability Reference 830 Rear Output/Modulation Input. RF output reduced up to 1.5 dB

Directions

Similar products from Signal Generation Equipment

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies