Fluke 744 Documenting Process Calibrator With Hart

US $2,199.99

  • Agawam, Massachusetts, United States
  • Jan 29th
Fluke 744 Documenting Process Calibrator with HART       Description   The 744 is a power multifunction documenting calibrator that lets you download procedures, lists, and instructions created with software-or upload data for printing, archiving, and analysis. The 744 also features a powerful built in HART® interface capable of performing nearly all the day-to-day tasks you now perform with a separate communicator.      Fluke 744 Documenting Process Calibrator with test leads, battery charger, and case in great condition. Comes with what is seen in photos.   Comes with:  Silicone Alligator Clips Test Probes  Battery Charger Data Cable Soft Case       Measurement Accuracy Voltage DC 110.000 mV  0.025%+0.015% * 1.10000 V  0.025%+0.005% * 11.0000 V  0.025%+0.005% * 110.000 V  0.05%+0.005% * 300.00 V  0.05%+0.005% * Voltage AC 20 to 40 Hz  2% + 10 40 to 500 Hz  0.5% + 5 500 to 1 kHz  2% + 10 1 kHz to 5 kHz  10% + 20 Ranges:  1.1000, 11.000, 110.00, 300V Current DC 30.000 mA  0.01% + 0.015% * 110.00 mA  0.01% + 0.015% * Resistance 11.000 ?  0.05% + 50 m? 110.00 ?  0.05% + 50 m? 1.1000 k?  0.05% + 500 m? 11.000 k?  0.1% + 10 ? Frequency 1.00 to 109.99 Hz  0.05 Hz 110.0 to 1099.9 Hz  0.5 Hz 1.100 to 10.999 kHz  5 Hz 11.00 to 50.00 kHz  50 Hz Pressure Accuracy  from 0.025% of range using any of 29 pressure modules.    Modules available for differential, gauge, vacuum, absolute, dual and high pressure.    (for detailed specifications refer to pressure modules in options and accessories) Note *  (% of reading + % of full scale)   Source Accuracy Voltage DC 110.000 mV  0.01%+0.005% * 1.10000 V  0.01%+0.005% * 15.0000 V  0.01%+0.005% * Current DC 22.000 mA (Source)  0.01%+ 0.015% * 22.000 mA (Simulate)  0.02% + 0.03% * Resistance 11.000 ?  0.01% + 20 m? 110.00 ?  0.01% + 40 m? 1.1000 k?  0.02% + 500 m? 11.000 k?  0.03% + 5? Frequency 0.00 to 10.99 Hz  0.01 Hz 11.00 to 109.99 Hz  0.1 Hz 110.0 to 1099.9 Hz  0.1 Hz 1100 to 21999 Hz  2 Hz 22.000 to 50.000 kHz  5 Hz Note *  (% of reading + % of full scale)   RTDs and Thermocouples Measure Accuracy: 10 ? Cu (427):  2 °C 100 ? Pt (3916):  0.3 °C 100 ? Pt (3926):  0.3 °C 100 ? Pt (385):  0.3 °C 200 ? Pt (385):  0.3 °C 500 ? Pt (385):  0.3 °C 1000 ? Pt (385):  0.3 °C 120 ? Ni (672):  0.3 °C note:  For 2-and 3-wire measurement, add 0.4°C E:  0.3 °C N:  0.5 °C J:  0.3 °C L:  0.3 °C K:  0.3 °C T:  0.3 °C U:  0.3 °C B:  0.9 °C R:  1.0 °C S:  0.9 °C C:  0.6 °C BP:  1.2 ?C XK:  0.4 ?C note:  Accuracy with external cold junction, for internal junction add 0.2 °C Source Accuracy: 10 ? Cu (427):  1 °C 100 ? Pt (3916):  0.1 °C 100 ? Pt (3926):  0.1 °C 100 ? Pt (385):  0.1 °C 200 ? Pt (385):  0.1 °C 500 ? Pt (385):  0.1 °C 1000 ? Pt (385):  0.1 °C 120 ? Ni (672):  0.1 °C note:  For 2-and 3-wire simulation, add 0.4 °C E:  0.2 °C N:  0.3 °C J:  0.2 °C L:  0.2 °C K:  0.3 °C T:  0.3 °C U:  0.3 °C B:  0.8 °C R:  0.9 °C S:  0.9 °C C:  0.6 °C BP:  0.5 ?C XK:  0.4 ?C note:  Accuracy with external cold junction, for internal junction add 0.2 °C   Technical Data Data Log Functions Measure functions:  Voltage, current, resistance, frequency, temperature, pressure Reading rate:  1, 2, 5, 10, 20, 30, or 60 readings/minute Maximum record length:  8000 readings (7980 for 30 or 60 readings/minute) Ramp Functions Source functions:  Voltage, current, resistance, frequency, temperature Rate:  4 steps/second Trip detect:  Continuity or voltage (continuity detection not available when sourcing current) Loop Power Function Voltage:  Selectable, 24 V or 28 V Accuracy:  5% Maximum current:  22 mA, short circuit protected Maximum input voltage:  30 V DC Step Functions Source Functions  Voltage, current, resistance, frequency, temperature Manual Step  Selectable step, change with arrow buttons Autostep  Fully programmable for function, start delay, stepvalue, time per step, repeat   Environmental Specifications Operating Temperature    -10 °C to +50 °C    -20 °C to +50 °C * Storage Temperature    -20 °C to +60 °C Dust/water resistance    Meets IP52, IEC 529 Operating Altitude    2800 m Note *  Except frequency and AC   Safety Specifications Agency Approvals    CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993   Mechanical & General Specifications Size    130 x 236 x 61 mm (5.1“ x 9.3” x 2.4”) Weight    1.4 kg (3 lbs., 1oz.) Batteries NiMH:  7.2V, 3.5 Ah Battery Life    >10 hours typical Battery Replacement    Via snap-shut door without opening calibrator; no tools required Side port connections    Pressure module connector    RS-232 connector for PC interface cable and for HART communication cable    Connection for optional battery eliminator Data storage capacity    1 week of calibration results 90 day specifications    The standard specification interval for the 744 is 1 and 2 years.    Typical 90 day measurement and source accuracy can be estimated by    dividing the one year "% of reading" or "%of output" specifications by 2.    Floor specifications, expressed as "% of full scale" or    "counts" or "ohms" remain constant.   Payment We accept PayPal payments as it is the most secure and offers more protection to buyers and sellers. PayPal also gives you the flexibility to pay with your checking account, debit, or credit cards.   Massachusetts buyers will pay 6.25% sales tax. Shipping We ship to all 50 states and most countries. This item will be shipped via UPS, USPS, or FedEx. We ship Monday through Saturday each week.  There will be a 1 day handling time on all orders to be shipped. Currently we ship from Massachusetts. We can sometimes combine shipping and reduce the rate if you win multiple items that can be shipped together. Items selling for more than $250 will have a required signature when delivered. After an item is shipped, the tracking info is put on PayPal. An e-mail will be sent to you by PayPal with your tracking information.   International Buyers - Please Note: Import duties, taxes, and charges are not included in the item price or shipping cost. These charges are the buyer's responsibility. Please check with your country's customs office to determine what these additional costs will be prior to bidding or buying.   Terms of Sale   We do our best to accurately describe each item in the listing and we offer a hassle-free 14 day return policy.  Buyer pays return shipping and upon receipt of the item and inspection a full refund will be issued. Please feel free to email any additional questions and/or concerns you have with an item. We will do our best so that you are completely satisfied with your purchase.   Contact Us Customer satisfaction is our number one goal. Your feedback is very important to us. Please contact us before leaving any negative or neutral feedback. We will work with you to solve any problems. If you have any questions we would be happy to assist you.      
Condition Used :
An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections.
Seller Notes Fluke 744 Documenting Process Calibrator with test leads, battery charger, and case in great condition. Comes with what is seen in photos.

Directions

Similar products from Process, Temperature & Pressure Calibrators

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies