Fluke 5500a Multi-product Calibrator

US $13,500.00

  • Crystal Lake, Illinois, United States
  • Mar 26th
Fluke 5500A Multi-Product Calibrator (no scope option) In perfect working order, recently calibrated. Ships in hard shell Pelican case with manual.  Voltage DC Range:  0 to ±1020V Best 1 Year Specification:  ±50 ppm of setting Current DC Range:  0 to ±11A Best 1 Year Specification:  ±0.01% of setting Resistance Range:  0 to 3.29.999 M? Best 1 Year Specification:  ±0.009% of setting Voltage AC Range:  1 mV to 1020V    10 Hz to 500 kHz, Sine Best 1 Year Specification:  ±0.03% of setting Current AC Range:  29 m A to 11A    10 Hz to 10 kHz, Sine Best 1 Year Specification:  ±0.06% of setting Capacitance Range:  0.33 nF to 1.1 mF Best 1 Year Specification:  ±0.25% of setting Thermocouple Source and Measure Range:  -250°C to +2316°C (11 types) Best 1 Year Specification:  ± 0.14°C of setting RTD Source Range:  -200°C to +630°C    (8 types) Best 1 Year Specification:  ±0.03°C of setting DC Power Range:  109 mW to 11 kW Best 1 Year Specification:  ± 0.08% of setting AC Power Range:  109 mW to 11 kW    45-65 Hz, PF=1 Best 1 Year Specification:  ± 0.15% of setting Phase Range:  0 to ± 179.99° Best 1 Year Specification: ±0.15° Frequency Range:  0.01 Hz to 2.0 MHz Best 1 Year Specification:  ±25 ppm of setting General Specifications Warm up Time    Twice the time since last warmed up, to a maximum of 30 minutes Settling Time    Less than 5 seconds for all functions and ranges except as noted Standard Interfaces    IEEE-488 (GPIB), RS-232, 5725A (5500A only) Temperature Performance Operating:  0°C to 50°C Calibration:  (tcal): 15°C to 35°C Storage:  -20°C to 70°C Temperature Coefficient    Temperature coefficient for temperatures outside tcal ± 5°C is 10% of the 90-day specification (or 1-year, as applicable) per °C Relative Humidity Operating:  < 80% to 30°C, < 70% to 40°C, < 40% to 50°C Storage:  < 95%, non-condensing Altitude Operating:  3,050m (10,000 ft) maximum Non-operating:  12,200m (40,000 ft) maximum Safety    Designed to comply with IEC 1010-1 (1992-1); ANSI/ISA-S82.01-1994; CAN/CSA-C22.2 No. 1010.1-92 Analog Low Isolation    20V EMC    Designed to comply with FCC Rules Part 15 Line Power Line Voltage (selectable):  100V, 120V, 220V, 240V Line Frequency:  47 to 63 Hz Line Voltage Variation:  : ± 10% about line voltage setting Power Consumption    300 VA Dimensions Height:  17.8 cm (7 in), standard rack increment, plus 1.5 cm (0.6 in) for feet on bottom of unit Width:  43.2 cm (17 in), standard rack width Depth:  47.3 cm (18.6 in) overall Weight (without options)    20 kg (44 lbs.) Absolute Uncertainty Definition    5500A and 5520A uncertainty specifications include stability, temperature coefficient, linearity, line and load regulation, and the traceability of the external standards used for calibration. You do not need to add anything to determine the total uncertainty of your calibrator for the temperature range indicated. Specification Confidence Interval    > 99% Stock photo, will replace with actual photos in next 48 hours. 
Some minor cosmetic wear, but in perfect working order. Recently calibrated.
Brand Fluke
MPN 5500A
Model 5500A

Directions

Similar products from Process, Temperature & Pressure Calibrators

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies