Fluke 1750 Three Phase Power Quality Recorder Fluke-1750

US $8,395.00

  • Toledo, Ohio, United States
  • Jan 29th
                                                              Content on this page requires a newer version of Adobe Flash Player.                      The Following Items Are Included: Fluke 1750 Three-Phase Power Recorder (BC# 18803) (4) Fluke 3140R 400Amp AC Clamps (5) Fluke Test Leads P/N: 2157713 (4-Black, 1-Green) (5) Alligator Clips (4-Black, 1-Green) Ethernet Cable Fluke 1750 Power Recorder Getting Started Guide Bag Of Fluke Wire Clips P/N: 2157607 Transcend 128MB Flash Card Fluke Power Recorder Software CD (5) International Adapters Power Cord User Manual On CD-ROM Hard Carrying Case (G)     BE SURE TO CHECK OUR EBAY STORE FOR OTHER ITEMS! This Item Has A Current Calibration!   Fluke 1750 Three-Phase Power Quality Recorder    Once power is applied the instrument automatically begins recording and LEDs give you assurance that the recorder is powered up and signals are within range – no more uncertainty that data is being recorded   Every cycle on every channel is simultaneously sampled providing complete analysis of power quality, harmonics, power and energy   Includes Hard Carrying Case & Accessories As Listed Above!     Working Condition: Excellent Condition: Refurbished Calibrated: Yes Warranty: 90 Day Exchange Warranty     Fluke 1750 Three-Phase Power Recorder Capture every measurement, every event, on every cycle, all the time with the Fluke 1750 Power Recorder. Outstanding accuracy and resolution provide complete visibility into your installation or distribution system. Easy to use The recorder automatically detects, scales, and powers current probes without needing batteries. Requiring only single-lead voltage connections enables safe and quick setups. Once power is applied the instrument automatically begins recording and LEDs give you assurance that the recorder is powered up and signals are within range – no more uncertainty that data is being recorded. The Fluke 1750 has an exclusive capture algorithm which makes certain all events are captured without the tedious setups and blind spots associated with threshold driven equipment. The PDA wirelessly interfaces with the recorder, allowing quick setup and verification with waveform displays, meter screens, and phasor diagrams. The built-in wireless technology allows you to control multiple instruments from a distance easily, without the need for a laptop computer (laptops can also be used when desired). Comprehensive power system data Every cycle on every channel is simultaneously sampled providing complete analysis of power quality, harmonics, power and energy. Cross channel current and voltage triggering captures event data on all input channels simultaneously, no matter which channel triggered the event. When periodic analysis of the waveform may be needed, the Snapshot mode captures waveforms at user defined intervals. Even dc signals can be recorded! Powerful data management Data is automatically stored on the internal flash memory that can store records for over a month without compression or overwriting. Data is retrieved via one of two quick and easy options: download the data onto the SD memory card without using your laptop, or transfer directly to your computer via Ethernet, using TCP/IP protocol.Voice, data, and picture annotations can be made via the PDA to flag important points in the data stream. Imagine being able to flag in your recorded data when a transfer switch was operated, or load changes were made. View data the way you want The new Fluke Power Analyze software revolutionizes your ability to analyze data. No need to worry about thresholds—with Fluke Power Analyze, thresholds can be modified after the data is recorded! And the easy-to-use user interface will display voltage as a phase-to-phase or phase-to-neutral reading. All the latest power quality standards are built-in IEC 61000-4-30 compliant measurement systems provide the confidence that all parameters are measured and calculated consistently with international standards. Automated EN50160 compliance reporting for rapid Pass/Fail testing. 600 V CAT IV and 1000 V CAT III safety rating Designed to help protect you and your equipment, the Fluke 1750 Three-Phase Power Recorder and accessories are all certified to meet the stringent safety standards for use in 600 V CAT IV and 1000 V CAT III environments. They are the first tools of their kind to carry the CAT IV rating and, therefore, can be used for most power connections and for all outlets in a low-voltage power distribution system. Applications: Long-term analysis: Uncover hard-to-find or intermittent issues; monitor critical equipment, capturing power quality events to correlate with equipment malfunction Power quality surveys: Quantify power quality throughout a facility, documenting results with professional reports  Quality of service compliance: Validate incoming power quality at the service entrance  Equipment Installation/Commissioning: Benchmark power system prior to install to insure quality of service Features: Power quality that meets the standard: All measurements comply with IEC61000-4-30 standards for correct evaluation of all measured values including voltage, current, power, harmonics, flicker etc. Quick and reliable configuration: PDA wireless “front panel interface” provides the ability to verify setup without a laptop along with a window into what the instrument is recording, even in awkward test locations. Threshold-free setup:  Apply thresholds after data is collected with Fluke Power Analyze Software so there is no need to worry about missed information due to incorrect set-up. Captures everything: Cross-channel and current triggering capture every measurement, on every channel, every time. Intuitive PC software: Easily analyze data and generate reports. Automated EN50160 reporting and compliance. Plug and play: Set up in minutes with self identifying current probes and single-lead voltage connections. No need to reconnect wires: Swap channels internally with the wireless PDA or PC when connections are not correct. Measure every parameter: voltage and current on three phases, neutral, and ground 5 MHz, 8000 Vpk waveform capture:  Get a detailed picture of even the shortest events. Specifications: General Power quality measurement standards Conformance IEC 61999-1-4 Class 1, IEC 61000-4-30, IEEE519, IEEE1159, IEEE1459 and EN50160 Clock/calendar Leap years, 24-hour clock Real-time clock accuracy Not more than ± 1 s/day Internal memory capacity for data At least 2 GB Maximum recording period At least 31 days Measurement time control Automatic Maximum number of events Limited only by the size of the internal memory Power requirements 100 to 240 V rms ± 10 %, 47-63 Hz, 40 W Operating time during interruptions (internal UPS operation) 5 minutes per interruption, 60 minutes total operating time without recharging Dimensions 215 mm x 310 mm x 35 mm (8.5 in x 12.2 in x 3.5 in) Mass (weight) 6.3 kg (14 lb) Input Measurement types One Phase Plus Neutral, One Phase IT No Neutral, One Phase Split Phase, Three Phase Wye, Three Phase Delta, Three Phase IT, Three Phase High Leg, Three Phase Open Leg, 2 Element Delta, 2 1/2 Element Wye Input channels Voltage: 4 channels, ac/dc Current: 5 channels Voltage channels Input resistance: 2 M? Input capacitance: < 20 pF Current input characteristics 2 V rms = full scale, 1 M? Input Impedance for ferro CTs, low impedance for Flexi-CTs Measuring method Simultaneous digital sampling of voltage and current. Digital PLL synchronized sampling, internal frequency reference used during voltage drops. Synchronization and sampling PLL-synchronization source The PLL synchronizes to the A-N voltage for wye power types, and to the A-B voltage for delta power types. All listed power types can be characterized as either wye or delta. PLL lock range 42.5 to 69 Hz Sampling frequency Voltage and current: 256 samples/cycle Inter-harmonics per IEC 61000-4-7: 2560 points/10 cycles (50 Hz), 3072 points/12 cycles (60 Hz) Transient Voltage: 5 MHz A/D resolution Voltage and current: 24 bits Transient voltage: 14 bits Voltage and current measurements Voltage measurement range AC voltage: 1000 V rms ± 10 % over range DC voltage: ± 1000 V + 10 % over range Voltage crest factor 3 or less Current measurement range Depends on current probe used Current crest factor 4 or less Voltage and current measurement accuracy RMS voltageEN 61010-1 2nd Edition; 2000 Voltage input unit: Contamination Level 2, Overvoltage Category 1000 V CAT III, 600 V CAT IV (anticipated overvoltage: 8000 V) Measurement type True rms calculated continuously: every cycle, every 1/2 cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by IEC 61000-4-30 Measurement uncertainty AC: ± 0.2 % reading ± 0.1 % full scale, above 50 V rms DC: ± 0.5 % reading ± 0.2 % full scale, above 50 V dc RMS current Measurement type True rms calculated continuously: every cycle, every 1/2 cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by standards Measurement uncertainty Ferromagnetic Clamps: ± (0.1 % full scale + 0.2 % reading + current sensor accuracy), valid for 5 % to 100 % of current sensor range Flexible Current Probes: ± (0.1 % full scale + 0.5 % reading + current sensor accuracy), valid for 5 % to 100 % of current sensor range Transient voltage (impulse) Measurement type Waveshape sampling Full scale 8000 V pk Sample resolution 200 nS Measurement uncertainty ± 5 % reading ± 20 V (test parameters: 1000 V dc, 1000 V rms, 100 kHz)EN 61010-1 2nd Edition; 2000 Voltage input unit: Contamination Level 2, Overvoltage Category 1000 V CAT III, 600 V CAT IV (anticipated overvoltage: 8000 V) Dip (Sag) and Swell Measurements Voltage swell (rms swell) Measurement type True rms (one cycle calculation by overlapping each half cycle - voltage between lines is measured for 3P3W lines and phase voltage is measured for 3P4W lines) Displayed data Amplitude and duration of swell Measurement uncertainty Same as rms voltage Voltage dip (rms sag) Measurement type True rms (one cycle calculation by overlapping each half cycle - voltage between lines is measured for 3P3W lines and phase voltage is measured for 3P4W lines) Displayed data Amplitude and duration of dip or interruption Measurement uncertainty Same as rms voltage Voltage dropout (interruption) Measurement type Same as voltage dip Power Measurements Calculated per IEEE1459 for best performance when distortion is present Measurement type True rms calculated continuously: every cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by standards Measurement accuracy +/- (voltage uncertainty + current uncertainty + current probe uncertainty) Frequency Measurement range 42.5 to 69 Hz Measurement source Same as PLL synchronization source Measurement accuracy ± 10 mHz (10 to 110 % of range, with sine wave) Power factor Measurement range 0.000 to 1.000 Measurement accuracy ± 1 digit from the calculation of each measured value (±3 digits for total) Displacement power factor Measurement method Calculated from the phase difference between voltage fundamental and current fundamental Measurement range - 1.000 (leading) to + 1.000 (lagging) Measurement accuracy ± 0.5 % reading ± 2 % full scale ± 1 digit Voltage unbalance and phase sequence Measurement method Positive sequence voltage divided by negative sequence voltage, per IEC 61000-4-30 Harmonic voltage and current Analysis window rectangular Analysis order 1st to 50th order Measurement accuracy Voltage / Current: 1st to 20th orders: ± 0.5 % reading ± 0.2 % full scale, 21st to 50th orders: ± 1 % reading ± 0.3 % full scale (current sensor accuracy must be included for current and power) Measurement method IEC 61000-4-7 Inter-harmonic voltage and current (intermediate harmonics) Analysis window rectangular Analysis orders 1.5 to 49.5th order Measurement method IEC 61000-4-7 Voltage flicker Measurement method as per EN 61000-4-15:2003: 10 min (Pst), 2 h (Plt) External Interface Specifications LAN interface Connector RJ-45 Speed and type 10/100 Base-T, auto MDIX Communications protocol TCP/IP over Ethernet Wireless controller interface Connection wireless (2.4 GHz radio) Speed up to 700 kbit/second Communications protocol Bluetooth SPP Environmental and safety specifications Operating environment Indoors or in covered area outdoors, up to 2000 m altitude (for compliance to IEC61010 standard) Storage temperature and humidity -20 °C to 50 °C, 80 % RH max, non-condensing Operating temperature and humidity 0 °C to 40 °C, 80 % RH max, non-condensing Maximum rated working voltage Voltage terminals 1100 V rms Voltage durability 5550 V rms ac for 1 minute, between voltage input terminals, voltage input terminals and current probes, and voltage input terminals and case (50/60 Hz, 1 mA sense current) Enclosure protection IP30 (per EN 60529) Standards conformance EMC EN 61326-1:1997+A1:1998 Class A EN 61000-3-2:1995+A1:1998+A2:1998 EN 61000-3-3:1995 Safety EN 61010-1 2nd Edition; 2000 Voltage input unit: Contamination Level 2, Overvoltage Category 1000 V CAT III, 600 V CAT IV (anticipated overvoltage: 8000 V)   Please check our Huge Inventory with savings of up to 80% off of retail on Cat5/5e/6 LAN Cable Certifiers and Fiber Optic OTDR's, Fusion Splicers, CATV Meters, Fiber Optic Kits, Sources, Meters, Tools, Network Analyzers and much more. Here is a Link to our Ebay Test Equipment Store. All of our Test Equipment is backed with a Full Warranty and unbeatable customer support & service. Please don't hesitate to contact us for a Quote on Something you don't see in our inventory, sometimes we have items that may have not been listed or processed yet.   Test Equipment Store Offers a wide range of Refurbished Telecom/ Datacom Tools and Test Measurement Equipment. Which includes Fiber Optic Test and Splicing tools, Fusion Splicers, OTDRs, Copper and Fiber Cable Certifiers, CATV Test Equipment, Cable and Antenna Analyzers, Network Analyzers and much more!   We carry a large inventory of quality refurbished and used test equipment from all the major manufacturers. If you are looking for multiple quantities or if we don't have a listing for a particular item that you are looking for. Please contact us as it may be fresh inventory waiting to be listed or we'll be glad to find it for you at the best price possible and put up an eBay listing for you!   Contact: Test Equipment Store eBay Sales Phone: 1-419-517-6681 Toll Free : 1-800-548-2381     We Ship World Wide!   We will attempt to ship your item(s) within 24 hours after payment has been received. To get a real-time shipping quote to your destination, enter your country and zip / postal code information into the shipping calculator and click "Get Rate". Many countries impose their own customs, duties, tariffs, taxes, etc. on items being shipped from a foreign country. We do not cover those cost's and we recommend that you contact your countries customs agency for that information. We Offer Multiple Quantity Price & Shipping Discounts, Email Us If You Are Interested In Larger Quantities.   UPS Ground   United States   USD 0.00 USPS Express Mail International (EMS)   Worldwide   USD 0.00   We accept credit card payment transactions via the online checkout system! The checkout process is designed so that it communicates with the merchant to confirm that payment has been made and cleared. Other methods of payment are outlined through the online checkout process. Winning bidders must contact us within 3 days after auction close if special payment arrangements are needed. Your payment is expected within 5 days after the auction close. Unpaid auctions will be forfeited after 5 days of the auction close and the Item(s) will be relisted for sale. Items will be shipped within 24 hours (1 Business Day) upon receipt of payment from the winning bidder. (Certain orders may take longer for processing due to comprehensive final service inspections) A Shipment Tracking number(s) will be provided to inform Buyers of their expected ETA (Estimated Time of Arrival). Tracking number(s) will be provided the same day as order shipment. Thank you ALL MAJOR CREDIT CARDS & PayPal ACCEPTED               Reach your goals with Kyozou eBay Sales Management
Condition:
Seller refurbished: An item that has been restored to working order by the eBay seller or a third party not approved by the manufacturer. This means the item has been inspected, cleaned, and repaired to full working order and is in excellent condition. This item may or may not be in original packaging. See the seller’s listing for full details. ...
Brand Fluke
Model Fluke 1750

Directions

Similar products from Voltage Monitors & Power Quality Analyzers

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies