Fluke 1587 Fc Digital Insulation Multimeter - Excellent Condition

US $410

  • Fort Mitchell, Kentucky, United States
  • Aug 21st
Fluke 1587 Digital FC Insulation Multimeter - 1000V. This item is for the core unit only and it does not have any leads or carrying case. The unit is in excellent condition and even has the original manufacturers static cling covering on the display, visible in the pictures if you look closely. Keep yourself safe. Find hidden problems faster. Put the paperwork down. Fluke Connect + Fluke's 1587 FC Insulation Multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily - all at a safe distance. Add diagnostics with Fluke Connect The Fluke 1587 FC is Fluke Connect-enabled so you can download the free Fluke Connect® Measurements app to your smartphone and gain additional functions, including: Safety first. Keep yourself out of harm’s way by monitoring your test measurements remotely. Prove your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone. Quickly find problems by saving and comparing measurements over time on a wireless device. PI/DAR timed ratio tests with TrendIt™ graphs to identify moisture and contaminated insulation problems faster Memory storage through Fluke Connect that saves measurements to your phone or the cloud and eliminates the need to write down results. Reduces errors and saves data for historical tracking over time Temperature compensation to establish accurate baselines and relevant historical comparisons Historical tracking and trending of assets to identify insulation degradation over time and allow real-time decisions to be made in the field with Fluke Connect® Assets (sold separately) Provides memory storage through Fluke Connect Measurements to eliminate the need to write down results Includes live circuit detection to prevent insulation test if voltage >30 V is detected Provides automated temperature compensation to establish accurate baselines Supports historical tracking and asset trending of assets to identify degradation over time with Fluke Connect® Assets (sold separately) Incorporates VFD low-pass filter for accurate variable frequency motor drive measurements Includes auto-discharge of capacitive voltage for added user protection Measures ac/dc voltage, dc millivolts, ac/dc milliamps, resistance, and continuity Includes capacitance, diode test, temperature, min/max, frequency measurements and insulation test smoothing reading Automatically powers off to save battery power Electrical Specifications AC voltage measurement Range 600.0 mV Resolution 0.1 mV Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3) 6.000 V Resolution 0.001 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3) 60.00 V Resolution 0.01 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3) 600.0 V Resolution 0.1 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3) 1000 V Resolution 1 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3) Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3) 1 kHz bandwidth Low-Pass Filter Voltage  Range 600.0 mV Resolution 0.1 mV Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) 6.000 V Resolution 0.001 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) 60.00 V Resolution 0.01 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) 600.0 V Resolution 0.1 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) 1000 V Resolution 1 V Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3) Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3) DC Voltage Measurement Range Resolution Accuracy ±(% of Rdg + Counts) 6.000 V dc 0.001 V ±(0.09% + 2) 60.00 V dc 0.01 V ±(0.09% + 2) 600.0 V dc 0.1 V ±(0.09% + 2) 1000 V dc 1 V ±(0.09% + 2) Input impedance  10 M (nominal), <100 pF Normal mode rejection ratio  >60 dB @ 50 Hz or 60 Hz Common mode rejection ratio  >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance) Accuracies apply to ± 100% of range DC Millivolts Measurement Range Resolution Accuracy ±(% of Rdg + Counts) 600.0 mVdc 0.1 mV ±(0.1% + 1) DC and AC Current Measurement AC 45 Hz to 1000 Hz Range 400 mA Resolution 0.1 mA Accuracy ±(% of Rdg+Counts) ±(1.5% + 2) Burden voltage (Typical) 2 mV/mA Range 60 mA  Resolution 0.01 mA  Accuracy ±(% of Rdg+Counts) ±(1.5% + 2) Burden voltage (Typical) 2 mV/mA DC Range 400 mA Resolution 0.1 mA Accuracy ±(% of Rdg+Counts) ±(0.2% + 2) Burden voltage (Typical) 2 mV/mA Range 60 mA Resolution 0.01 mA Accuracy ±(% of Rdg+Counts) ±(0.2% + 2) Burden voltage (Typical) 2 mV/mA Overload 600 mA for 2 minutes maximum Fuse protection for mA input 0.44 mA, 1000 V, IR 10 kA AC conversion Inputs are ac-coupled and calibrated to the rms value of sine wave input Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor 1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3. 1 kHz bandwidth Ohms Measurement Range Resolution Accuracy +(% of Rdg+Counts) 600.0 0.1 ±(0.9% + 2) 6.000 k 0.001 k ±(0.9% + 2) 60.00 k 0.01 k ±(0.9% + 2) 600.0 k 0.1 K ±(0.9% + 2) 6.000 M 0.001 M ±(0.9% + 2) 50.0 M 0.01 M ±(1.5% + 3) Overload protection  1000 V rms or dc Open circuit test voltage  <8.0 V dc Short circuit current  <1.1 mA Accuracies apply from 0% to 100% of range Up to 80% relative humidity Diode Test Diode test indicatin Display voltage drop: 0.6 V at1.0 mA nominal test current: Accuracy ±(2% + 3) Continuity Test Continuity indication Continuous audible tone for testresistance below 25 and off above 100 . Maximum Reading; 1000 Open circuit voltage <8.0 V Short circuit current 1.0 mA typical Overload protection 1000 V rms Response time >1 m sec Frequency Measurement Range Resolution Accuracy ±(% of Rdg+Counts) 99.99 Hz  0.01 Hz  ±(0.1% + 1) 999.9 Hz  0.1 Hz  ±(0.1% + 1) 9.999 kHz  0.001 kHz  ±(0.1% + 1) 99.99 kHz  0.01 kHz  ±(0.1% + 1) Frequency Counter Sensitivity 600.0 mV ac  V ac Sensitivity (RMS Sine Wave)  5 Hz to 20 kHz  100.0 mV  V ac Sensitivity (RMS Sine Wave)  20 kHz to 100 kHz 150.0 mV  DC Trigger Levels to 20 kHz NA 6.0 V  V ac Sensitivity (RMS Sine Wave)  5 Hz to 20 kHz  1.0 V  V ac Sensitivity (RMS Sine Wave)  20 kHz to 100 kHz 1.5 V  DC Trigger Levels to 20 kHz -400.0 mV and 2.5 V 60.0 V  V ac Sensitivity (RMS Sine Wave)  5 Hz to 20 kHz  10.0 V  V ac Sensitivity (RMS Sine Wave)  20 kHz to 100 kHz 36.0 V  DC Trigger Levels to 20 kHz 1.2 V and 4.0 V 600.0 V  V ac Sensitivity (RMS Sine Wave)  5 Hz to 20 kHz  100.0 V  V ac Sensitivity (RMS Sine Wave)  20 kHz to 100 kHz - DC Trigger Levels to 20 kHz 12.0 V and 40.0 V 1000.0 V  V ac Sensitivity (RMS Sine Wave)  5 Hz to 20 kHz  300.0 V  V ac Sensitivity (RMS Sine Wave)  20 kHz to 100 kHz - DC Trigger Levels to 20 kHz 12.0 V and 40.0 V Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy Usable to 100 kHz with full scale input Capacitance Range  Resolution  Accuracy ±(% of Rdg+Counts) 1000 nF  1 nF ±(1.2% + 2) 10.00 F  0.01 F ±(1.2% + 2) 100.0 F  0.1 F ±(1.2% ±90 counts) 9999 F  1 F ±(1.2% ±90 counts) Temperature Measurement Range  Resolution  Accuracy ±(% of Rdg+Counts) -40 ° C to 537 ° C  0.1 °C  ±(1% + 10 counts) -40 ° F to 998 ° F  0.1 °F  ±(1% + 18 counts) Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument Insulation Specifications Measurement range 0.01 M to 2 G Test voltages 50, 100, 250, 500, 1000 V Test voltage accuracy +20%, -0% Short-circuit test current 1 mA nominal Auto discharge Discharge time <0.5 second for C = 1 F or less Live circuit detection Inhibit test if terminal voltage > 30 V prior to initialization of test Maximum capacitive load Operable with up to 1 F load Output Voltage 50 V (0% to +20%) Display range 0.01 to 6.00 M Resolution 0.01 M Test current 1 mA @ 50 k Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts) Display range 6.0 to 50.0 M Resolution 0.1 M Test current 1 mA @ 50 k Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts) 100 V (0% to +20%) Display range 0.01 to 6.00 M Resolution 0.01 M Test current 1 mA @ 100 k Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts) Display range 6.0 to 60.0 M Resolution 0.1 M Test current 1 mA @ 100 k Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts) Display range 60 to 100 M  Resolution 1 M Test current 1 mA @ 100 k Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts) 250 V (0% to +20%) Display range 0.1 to 60.0 M  Resolution 0.1 M Test current 1 mA @ 250 k  Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) Display range 60 to 250 M  Resolution 1 M Test current 1 mA @ 250 k  Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) 500 V (0% to +20%) Display range 0.1 to 60.0 M Resolution 0.1 M Test current 1 mA @ 500 k  Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) Display range 60 to 500 M Resolution 1 M Test current 1 mA @ 500 k  Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) 1000 V (0% to +20%) Display range 0.1 to 60.0 M  Resolution 0.1 M Test current 1 mA @ 1 M Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) Display range 60 to 600 M  Resolution 1 M Test current 1 mA @ 1 M Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts) Display range 0.6 to 2.0 G  Resolution 100 M  Test current 1 mA @ 1 M Resistance accuracy ±(% of Rdg + Counts) ±(10% + 3 counts) General Specifications Maximum voltage applied to any terminal and common 1000 V Storage temperature -40 °C to 60 °C (-40 °F to 140 °F) Operating temperature -20 °C to 55 °C (-4 °F to 131 °F) Temperature coefficient 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F) Relative humidity Noncondensing 0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F) 0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F) 0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F) Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument Radio frequency communication 2.4 GHz ISM Band Radio frequency certification FCC: T68-FBLE, IC: 6627A-FBLE Electromagnetic Compatibility  International IEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.  There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected. Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. Enclosure protection IEC 60529: IP40 (non-operating) Safety IEC 61010-1 Pollution Degree 2 IEC 61010-2-033 CAT IV 600 V / CAT III 1000 V Batteries  Four AA batteries (IEC LR6) Battery life Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 M with a duty cycle of 5 seconds on and 25 seconds off. Size (H x W x L) 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in) Weight 550 g (1.2 lb) Altitude Operating 2000 m Storage 12,000 m Over-range capability 110% of range except for capacitance which is 100% Frequency overload protection <107 V Hz Fuse protection for mA input 0.44A, 1000 V, IR 10 kA .
Condition:
Used: An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections. ...
Brand Fluke
Measurement Category CAT III
Display Digital
Test/Measurement Functions Continuity Test, AC Current, Capacitance, DC Current, AC Voltage, DC Voltage
Form Factor Handheld
Maximum Input Voltage 1000V
Features Battery Door Access, Auto Power Off, Auto-Ranging
AC Voltage Range 1000
DC Voltage Range 1000
MPN 1587FC
Custom Bundle No
UPC 0095969796620

Directions

Similar products from Multimeasuring devices

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies