g # B024A CNC 2.2KW Water-Cooled Spindle Motor + 2.2KW Inverter VFD+ Mount + 13pcs ER20 collet water-pump + Pipes full kit Product description Item Description: Spindle Specification: Specification: Φ80mm x Length:214mm Power: 2.2 KW Voltage: 220V~250V Frequency: 400 Hz Speed: 8000-24000 R/min Water Cooling ER20 ( 4mm,6mm,8mm,12mm,12.7mm) collet chuck by your choice Runout off: less than 0.005mm Grease Lubrication VFD Specification: Series HY inverters Control Mode SPWM Input Power 230V class:220±15% 5-Digits Display & Status Indicator Lamp Displaying frequency, current, revolution, voltage, counter, temperature, FOR or REV rotation, and fault, etc. Communication Control RS-485 Working Temperature -10~40℃ Humidity 0-95% Relative Humidity(without dew) Vibration Below 0.5G Frequency Control Range 0.1~400.0Hz Accuracy Digital: 0.1%(-10~40℃); Analog: 0.1% (25±10℃) Setting Resolution Digital: 0.1Hz; Analog: 1‰ of max. Operating frequency Output Resolution 0.1Hz Operator Setting Method Press directly ← ∧ ∨ to set. Analog Setting Method External Voltage 0-5V,0-10V,4-20mA,0-20mA. Other Functions Frequency lower limit, starting frequency, stopping frequency, three skip frequencies can be respectively set. General Control Ramp Control Selectable 4-speed steps ramp-up and -down time (0.1-6500s). V/F Curve Set V/F curve at will. Torque Control Torque increase settable by max. 10.0%. The starting torque can reach 150% at 1.0Hz. Multi-Inputs 6 multi-function input terminals for 8–speed steps control, program operation, switching of 4-speed Ramp, UP/DOWN function, counter, external emergency stop and other functions. Multi-Outputs 5 multi-output for displaying of running, zero speed, counter, external abnormity, program operation and other information and warnings. Other Functions Auto Voltage Regulation(AVR), Decelerating Stop or Coasting Stop, DC Braking, Auto Reset and Restart, Frequency Track, PLC Program Control, Traverse Control,Drawing Control?Auto Energy Saving, Carrier Adjustable (Up to 20KHz), etc. Protection Functions Overload Protection Electronic relay protection motor drive Drive(for constant torque 150%/1 min. for the kinds of fan 120%/1min.) Fuse Protection When the fuse breaks , the motor will stop. Over-voltage 220V class:DC Voltage >400V 380V class:DC Voltage >800V Under-voltage 220V class:DC Voltage
By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.