Capacitor Capacitance Cap Esr Meter Tester Combo Dmm Mesr-100 +m4070 Lcr Meter

US $106.88

  • Shenzhen, China
  • Jan 29th
Capacitor Capacitance Cap ESR Meter Tester Combo DMM MESR-100 + M4070 LCR  meter Features: JINGYAN MESR-100  V2 Auto-ranging capacitor ESR and Low Ohm Meter Measuring range  from 0.001 to 100.0R, support IN CIRCUIT Testing. Using true 100 KHz  sine wave to measure the ESR value, which is equal to the testing method of  capacitor manufacturer. In the market,  there is some technique using short pulse method to testing, but the value will  be varying vs the capacitance and sometimes reading is different from the  manufacturer's value.  What is ESR of  capacitor? There is a series  resistor inside capacitor, using 100kHz to remove the impedance 1/(2*pi*F*C),  the impedance become small, and we can then measure the true series resistor  value. A bad E-capacitor  will have larger ESR and create large ripple rather than filtering noise.  Normally, a big capacitor is larger than 3 ohm. Using this theory,  we can measure the capacitor is bad/ damaged or good in  condition. Because our ESR  meter only applies less than 15mV DC or peak to peak on a good capacitor, as a  result we can use it as in circuit test. Because this low testing voltage, it  cannot turn on the semiconductor inside a circuit under  testing. During repairing  TV, LCD, Audio board, etc. we can in circuit testing the capacitor is good or  not.  *Dual terminal,  for fast and easy inspect general capacitor or resistor, a printed ESR table for  fast check Compare MESR100  old V1 and new V2 Improvement: 1)     Change square wave to sine wave  100 KHz, reduce square wave’s high frequency component, and affect the reading  passing the test leads and capacitor. 2)     Higher Resolution up to 0.001  ohm. 3)     128X64 dot matrix LCD, with  more larger value display and information 4)     Embedded 25V capacitor table at  LCD, auto display the capacitor is good or bad reference to common 25V  electrolytic capacitor. 5)     New plastic case, curve design  for hand carrying. New stand for 60 degree stand on desk. 6)     Use 2X AA battery, more  convenience and longer battery life than 9V battery. 7)     Support external USB power,  using standard micro-USB port.  Specification: Range Accuracy  (After Zero, tested with 1,10,100R resistor) Refresh  Time  (Manual Mode) *Auto mode  take  0 to 2s more time depend on value 0.000 to  1.000R 1%+2Digit ~0.4s 1.000 to  10.00R 1%+1Digit ~0.4s 10.00 to  100.0R 2%+1Digit ~0.4s *Accuracy maybe affected by the  test lead’s length and contact point resistance. Standard test leads is 15cm,  for longer test leads need special shielding to affect the EMI inference (Can  contact sales’ person for more detail)   1)     Accuracy:  Up to 1%  (detail on above table) Wide Measurement Range:  >1uF (for 0.1uF the error will be  larger on equation 1/(2*pi*F*C) @ 100Khz ) 2)     High Resolution: 4  digit, or 0.001Ohm @ 1 Ohm range 3)     Measuring voltage: <~40mV  RMS (TESTING VOLTAGE) 4)     Clamping voltage: ~0.15V (open  voltage) 5)     Battery 2X AA 1.5V  battery 6)     External Power: 5V micro USB 7)     Operating current  0.02A 8)     Battery Life time: >80  Hours  Operating  Introduction: 1)     POWER ON Press and hold the  ON/ OFF circle orange button for 2 to 3 second to power on. Press and release  the ON/ OFF button to shut down meter. 2)  AUTO/ MANUAL mode: i)  Auto Range: Press  and release the RANGE button and at the first line of LCD will show  “AUTO:" At auto mode meter  will automatically select the best range to detect. ii) Manual  Range: Scroll the manual  range from 1R, 10R and 100R range by press and release the RANGE  button In LCD will show  MANUAL at first LCD line and show at second line: 0-1R, 1-10R and  10-100R. 3) 1  Key Zero: Short circuit the  test leads’ terminal, cancelling the wire resistance. Press and release  the “ZERO" button, LCD shows “ZERO" and wait the zero  disappear. If you are using  the meter array socket, you need to use a short pin to short circuit to set  zero. 4)  Backlight: LCD backlight will  on during power on 5) Auto  Sleep: Around 10 hours  for not testing, it will shut down automatically to save  power. 6) OVERFLOW or  OL: Display overflow  when the value is out of range, you can check that you are zero  correctly. 7) ESR  TABLE: It is for  reference only, different manufacturer of capacitor has different ESR, better to  test a good cap ESR and compare with what you are testing, usually bad cap with  higher ESR few times larger than good one. 8) SOFTWARE  ESR: Put the 25V  Electrolytic capacitor value to LCD, and compare, GOOD if C <  XXuF, means the capacitor maybe good condition if it is less than  XXuF 9) PLASTIC  STAND: If you don’t use  the stand, press and push the lock position:   Package  includes: 1  unit MESR-100  V2 1  pair 15cm test clips (as photo) LCR M4070 AutoRanging LCR Meter Up to 100H 100mF 20MR Download Manual: http://www.mib-tech.com/product_manual.html M4070 LCR METER Special Features:  M4070 LCR meter is  auto-ranging component tester, can drive up to 500 KHz, suitable for small  value capacitor and inductor measurement. It provides very stable and high  resolution measurement up to 5 digits. Meter can measure 0.00pF to  100.00mF capacitance, 0.000uH to 100.00H and 0.00?? to 10.000M?This meter is using two technique measurement, LC oscillation  and RC oscillation. LC is much suitable for small value measurement and RC  for high value capacitance. *Discharge Capacitor before Testing!! Features: -       Fully auto-ranging designed  -           High resolution, up to 5 digit display, most finest resolution:  0.01pF, 0.001uH, 0.01R -           High stability and measurement range for L/ C/  R -           USB charging with rechargeable battery  inside -           Large LCD display with backlight -           USB PC program, can take record and pass and fail component  sorting function. Measurement Photo: Specification: Model: M4070 LCR Meter  Series LCR Testing  Parameter Main Parameter: L / C / R   Testing frequency  C: 10 to  500Khz L: 10 to  360Khz Testing  Method Auto select LC and RC  Oscillation Calibration Power on auto calibrate with  internal reference capacitor Testing  voltage ~1.5Vrms Best  Tolerance L: 1% +1  Digit C: 1% +1  Digit R: 0.5% +1  Digit LCD update or Testing time (*  vary on component value) <3/s, (e.g. 100mF Capacitor  <30s) Range  Selection Automatically Zeroing Open / short circuit  Terminal Mini-USB(Virtual Com  Port) Display  Range C  0.00pF ~100.000mF (pF/nF/uF/mF) L  0.000uH ~ 100.000H                  (uH/mH/H) Hz (LC Oscillation  Frequency)) 0 to  900000Hz (s)  (RC Constant  Time) 0.000 to  99.999 R  0.00 ? ~  20.000 M?                        (?/k?) LCD Display 128X64 Dot Matrix, with  backlight Fuse  Protection 200mA Charging  terminal Mini-USB  (500mA) Battery internal 3.7V Li-polymer  Number of Testing  Terminal Main 3, Secondary  4 Reading  Display Max. 99999  COMPARSION WITH OTHER LCR METER: Measurement  Comparasion Capacitor (Marked  Value)) TH2822A (10KHz) LC200A M4070 Reading Frequency Reading Frequency (Hz) % with TH2822A Absolute % Error Reading Frequency (Hz) % with TH2822A Absolute % Error 5pF 5.41 10Khz 5.06 654224 6.47 6.47 5.37 490920 0.74 0.74 33pF 31.54 10Khz 30.03 645310 4.79 4.79 31.29 485340 0.79 0.79 75pF 73.6 10Khz 71.42 634132 2.96 2.96 71.19 477160 3.27 3.27 330pF 341.33 10Khz 332.5 571000 2.59 2.59 333.25 431890 2.37 2.37 1000pF 949.7 10Khz 940.6 474000 0.96 0.96 946.37 361110 0.35 0.35 68nF 54.68 10Khz 54.7 107200 -0.04 0.04 56.614 61900 -3.54 3.54 10nF 11.473 10Khz 11.73 194900 -2.24 2.24 11.52 141520 -0.41 0.41 100nF 70.87 10Khz 68.38 102000 3.51 3.51 69.555 62700 1.86 1.86 1uF 1.0708 100Hz 1.05 1.94 1.94 1.0883 -1.63 1.63 33uF 33.286 100Hz 34.9 -4.85 4.85 34.735 -4.35 4.35 220uF 196.78 100Hz 205 -4.18 4.18 203.69 -3.51 3.51 470uF 448.7 100Hz 475 -5.86 5.86 468.04 -4.31 4.31 2.2mF 2.0203 100Hz 2.15 -6.42 6.42 2.1142 -4.65 4.65 22mF 19.408 Series  19.8 -2.02 2.02 20.04 -3.26 3.26 5pF to 100nF  is small capacitor with ceramic . While 1uF to 22mF is Electrolytic  Capacitor. Small Cap Standard Deviation  %                     Compare with TH2822A 2.76 2.07 Large Cap Standard  Deviation  %                    Compare with TH2822A 3.10 1.11 Small Cap Average Abs  Error  %                     Compare with TH2822A 2.94 1.67 Large Cap Average Abs  Error  %                    Compare with TH2822A 4.21 3.62 Model of commom LCR meter DM4070 TH2822A LC200A M4070 Price (Loweset in Ebay @2012 Oct 16) 34.8USDD 213USD 35.98USD 59USD Testing Frequency 1kHz 100Hz,120Hz,1kHz,10kHz 500khz 10  to 500khz Capacitor 0.1 pF ~ 2000 uF 0.00pF  ~20.000mF 0.00pF  to 100.000mF 0.00pF  to 100.000mF Inductor 0.1uH ~ 20H 0.00uH  ~ 1000.0H 0.000uH  to 100.000H 0.000uH  to 100.000H Resistor 0.01R ~ 20MR 0.0000  ? ~ 10.000 M? NAA 0.00  to 10.000MR Minor measurement (Phase, %, D) No Yes No No Resolution 1999 40000 9999 99999 Capacitor Accuracy 2.50% 0.25% 1% 1% Inductor Accuracy 2.50% 0.25% 1% 1% Resistor Accuracy 0.50% 0.25% NA 0.50% Range Manual  Select Fully  Auto Semi  Auto (need manual select large or small scale) Fully  Auto Terminal & Socket 2X  Test Lead, 2X Socket 2X  Test Lead, 2X Socket 2X  Test Lead 2X  Test Lead, 2X Socket PC Program No Yes No Yes PC Terminal No USB No USB Zero Function No Yes Yes Yes Power 9V  Battery 9V  Battery /12V External Power 4XAA  Battery /External 5V Power Li  Polymer rechargeble / USB power  Fuse Protection (Capacitor Measurement) Self  Discharge No No Yes Low Battery Alarm Yes Yes Yes Yes Display Segment  LCD  Segment  LCD Dual display reading 16X2  Character LCD 128X64  dot matrix LCD  Backlight NO Yes Yes Yes Includes: 1) 1 pcs M4070 2) USB Cable 3) Download labview  software: http://www.mib-tech.com/product_manual.html Shipping & Payment: Here Offer 100% Satifiation  Service,Inlucde re-send item&refund payment; All items here offer 1 year warranty It is not my Duty for Custom Tax All items will be shipped via int'l air  mail, the time normally takes 7-15 business days, may be later  arrived if the item is checked by custom; We only accept paypal payment.

Directions

Similar products from Capacitance Testers & Meters

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies