Adinstruments Powerlab/4st Ml760/w Ecg Emg Eeg Physiology Teaching

US $3,000.00

  • San Diego, California, United States
  • Mar 11th
ADInstruments PowerLab/4ST ML760/W ECG EMG EEG Physiology Teaching We gladly ship to most countries Scroll down for more Photos and details ADInstruments PowerLab 4ST ML760 ECG EMG EEG DAQ system for Lab Research and Physiology Teaching Complete Kit This is a complete kit with many extras included. see the list at the bottom for more details The PowerLab/4ST Teaching System is a high-performance special combination recording unit for physiology teaching, with PowerLab software. It has been designed to cover the broad experimental requirements in Life Science education, from introductory human physiology laboratory courses to neurophysiology experiments. The PowerLab/4ST features:    * 2 isolated biological inputs (with common ground)    * 1 constant-current isolated stimulator output    * 2 non-isolated, single-ended or differential analog inputs    * 2 analog outputs    * 2 Pod inputs    * external trigger, and    * audio output. The PowerLab/4ST ships with PowerLab software (Chart, Scope and Chart extensions), the Physiology Experiments Manual (a documented and illustrated collection of some 11 experiments comprising over 50 exercises), and settings files for an automatic and immediate start to each experiment. In addition, new teaching experiments and settings files are available to download from our new Teaching Resources web site. The simplicity of the system lets your students concentrate on the results, not the equipment. The PowerLab/4ST connects via SCSI or USB to Windows or Macintosh computers, and can record at up to 200 000 samples per second.   Specifications: Analog Input, Channels 1 and 2 Input configuration: 2 single-ended or differential (the latter only through the Pod connectors) Input ranges: mV to V full scale in 2:5:10 steps Maximum input voltage: V Input impedance: ~1 megohm Low-pass filtering: Anti-aliasing filter 1 Hz to 20 kHz software-selectable) AC coupling: AC coupling bandwidth 0.16 Hz to 30 kHz Frequency response (-3 dB): 20 kHz @ V full scale, all ranges (no 50 Hz low-pass filter) DC drift: Software-corrected Bio Amp Input, Channels 3 and 4  Input configuration: 2 differential channels with common isolated ground reference  Input impedance: 100 megohm to ground using supplied Bio Amp cable and leads  Safety: Approved to IEC601-1 BF (body protection) standard  Isolation rating: 4000 V ACrms for 1 minute  Amplification ranges: to mV full scale in 2:5:10 steps Non-linearity:

Directions

Similar products from Data Loggers and Data Acquisition Cards

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies