Abb A26-30-01 Contactor, 30a, 600vac Max, 200-600vac, 7.5-25hp, 110-120v Coil

US $290

  • Durham, Connecticut, United States
  • Jun 9th
For sale here is a ABB A26-30-01 Contactor. This contactor has seen slight use, yet despite such use, is in great and proper working order. All products are professionally tested.  General Information Extended Product Type: A26-30-01 48V 50Hz / 48V 60Hz Product ID: 1SBL241001R8301 EAN: 3471522061836 Catalog Description: A26-30-01 48V 50Hz / 48V 60Hz Contactor Long Description: A26 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available Technical Number of Main Contacts NO: 3 Number of Main Contacts NC: 0 Number of Auxiliary Contacts NO: 0 Number of Auxiliary Contacts NC: 1 Rated Operational Voltage: Main Circuit 690 V Rated Frequency (f): Supply Circuit 50 Hz Supply Circuit 60 Hz Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 45 A acc. to IEC 60947-5-1, q = 40 °C 16 A Rated Operational Current AC-1 (Ie): (690 V) 40 °C 45 A (690 V) 55 °C 40 A (690 V) 70 °C 32 A Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 55 °C 26 A (380 / 400 V) 55 °C 26 A (415 V) 55 °C 26 A (440 V) 55 °C 26 A (500 V) 55 °C 22 A (690 V) 55 °C 17 A Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 6.5 kW (380 / 400 V) 11 kW (415 V) 11 kW (440 V) 15 kW (500 V) 15 kW (690 V) 15 kW Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3 Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3 Rated Operational Current AC-15 (Ie): (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 50 A Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 210 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 45 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 90 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 110 A for 0.1 s 140 A for 1 s 100 A Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 420 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 170 A Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour Rated Operational Current DC-13 (Ie): (125 V) 1.1 / 138 A (24 V) 6 / 144 A (250 V) 0.55 / 138 A (48 V) 2.8 / 134 A (72 V) 2 / 144 A Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V Rated Impulse Withstand Voltage (Uimp): 8 kV Mechanical Durability: 10 million Maximum Mechanical Switching Frequency: 3600 cycles per hour Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at ?
Condition:
Used: An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections. ...
Brand ABB

Directions

Similar products from Circuit Breakers & Surge Protectors

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies